These Blowers normally use forward curved impellers made of galvanized
steel, which are press fitted on the Rotor of External Rotor Motor, making
the unit compact. Single inlet signifies that the Air is drawn from one
side of the Blower only. The Rotor with impeller is dynamically Balanced
in two planes, for vibration free running during its entire life. The
assembly of Motor and Impeller is essentially mounted in a technically
designed Housing for optimum performance. The External Rotor Motor is
cooled with the air stream flowing over it.
|
|
|
|
|
Impeller Diam. |
: |
125 to 240 mm |
|
Air Flow |
: |
175 to 1200 m3/hr. |
|
Input Voltage |
: |
110, 220, 440 V AC (50/60
Hz.) |
|
Power Input |
: |
20 to 350 W |
Note
: Motor used with CE Mark and confirms to EN 60335-1 standards.
|
| Model |
A |
B |
C |
D |
E |
F |
| SI*/125*/* |
92 |
125 |
15 |
50 |
70 |
58 |
| SI*/140*/* |
92 |
140 |
25/35 |
60 |
85 |
58 |
| SI*/160*/* |
92 |
160 |
35 |
63 |
89 |
58 |
| SI*/180*/* |
110 |
180 |
35/45 |
75 |
115 |
90 |
| SI*/235*/* |
110 |
235 |
45 |
95 |
120 |
90 |
| Model |
Impeller
Diam. |
A |
B |
C |
D |
E |
F |
G |
H |
J |
| SI*/125*/H |
125 |
65 |
50 |
105 |
90 |
85 |
70 |
53 |
175 |
170 |
| SI*/140*/H |
140 |
80 |
75 |
130 |
125 |
115 |
105 |
80 |
190 |
185 |
| SI*/160*/H |
160 |
80 |
92 |
120 |
130 |
100 |
108 |
82 |
234 |
240 |
| SI*/180*/H |
180 |
95 |
110 |
137 |
150 |
114 |
128 |
93 |
260 |
275 |
| Centrifugal Blowers
Single Inlet 1400 RPM |
| MODEL |
Rotor
Diam.
mm. |
Impeller
Diam.
mm. |
Voltage
V |
Amps
A |
Input
Watts
W |
Air
Volume
m3/hr |
| SI
23/14014/H |
92 |
140 |
230 |
0.28 |
65 |
370 |
| SI
23/16014/H |
92 |
160 |
230 |
0.40 |
90 |
450 |
| SI
23/18014/H |
110 |
180 |
230 |
0.50 |
110 |
600 |
| SI
44/18014/H |
110 |
180 |
415 |
0.35 |
140 |
650 |
| SI
23/23514/H |
110 |
235 |
230 |
1.00 |
220 |
900 |
| SI
44/23514/H |
110 |
235 |
415 |
0.60 |
250 |
950 |
|
| Air
Flow Curves For Single Inlet Centrifugal Blower |
| 1400 RPM |
 |
| Conversion
100pa = 0.4 H2O 100m3/Hr =
60cfm |
Centrifugal Blowers
Single Inlet 2800 RPM |
| MODEL |
Rotor
Diam.
mm. |
Impeller
Diam.
mm. |
Voltage
V |
Amps
A |
Watts
W |
Air
Volume
m3/hr |
| SI
23/12528/H |
92 |
125 |
230 |
0.28 |
65 |
180 |
| SI
23/14028/H |
92 |
140 |
230 |
0.32 |
70 |
485 |
| SI
44/14028/H |
92 |
140 |
415 |
0.25 |
75 |
500 |
| SI
23/16028/H |
92 |
160 |
230 |
0.65 |
150 |
600 |
| SI
44/16028/H |
92 |
160 |
415 |
0.40 |
150 |
650 |
| SI
23/18028/H |
110 |
180 |
230 |
1.25 |
280 |
850 |
| SI
44/18028/H |
110 |
180 |
415 |
0.75 |
300 |
850 |
|
|
|
Air
Flow Curves For Single Inlet Centrifugal Blower |
|
2800 RPM |
 |
| Conversion
100pa = 0.4 H2O 100m3/Hr =
60cfm |
|
 |
Cooling AC/DC Drives |
|
 |
Air Balloons as an
advertising media |
|
 |
HVAC applications |
|
 |
Applications with
relatively small Air Volumes with high static pressure, and low
noise levels |
|